piwik-script

Deutsch Intern
    X-Ray Microscopy

    Conference Proceedings and Journal Publications

    J. Dittmann, A. Balles, S. Zabler
    Optimization Based Evaluation of Grating Interferometric Phase Stepping Series and Analysis of Mechanical Setup Instabilities
    Journal of Imaging, Volume 4, Issue 6, 7 June 2018
    https://doi.org/10.3390/jimaging4060077

    J. Dittmann, S. Zabler
    Autocalibration of cone beam CT projection matrices based on arbitrary traceable features within a regular tomographic scan
    5th International CT-Meeting, Salt Lake City, USA, May 20-23 2018
    http://www.ucair.med.utah.edu/CTmeeting/

    M. Ullherr, A. Balles, C. Fella, S. Zabler
    Using measurements of the spatial SNR to optimize phase contrast X-ray imaging

    Science Direct, Volume 877, 1 January 2018, Pages 44-5
    https://doi.org/10.1016/j.nima.2017.09.044

    K. Dremel, T. Fuchs
    Scatter simulation and correction in computed tomography: A reconstruction-integrated approach modelling the forward projection
    NDT & E International, Volume 86, Pages 132-139, 2017
    http://doi.org/10.1016/j.ndteint.2016.12.002

    J. Dittmann
    Efficient ray tracing on 3D regular grids for fast generation of digitally reconstructed radiographs in iterative tomographic reconstruction techniques
    Submitted Sept 2016
    https://arxiv.org/abs/1609.00958

    J. Dittmann, S. Zabler, R. Hanke
    Nested Tomography: Application to Direct Ellipsoid Reconstruction in Anisotropic Darkfield Tomography
    In Proceedings of the Conference on X-ray and Neutron Phase Imaging with Gratings, XNPIG 2017, Zurich, Switzerland, 12–15 September 2017; pp. 49–50.
    https://www.psi.ch/xnpig2017

    J. Dittmann, R. Hanke
    Simple and efficient raycasting on modern GPUs' read-and-write memory for fast forward projections in iterative CBCT reconstruction
    14th International Meeting on Fully 3D Image Reconstruction, Xi'an, China, June 2017
    http://onlinelibrary.fully3d.org/papers/2017/Fully3D.2017-11-3203040.pdf

    J. Dittmann, M. Trapp, K. Dremel
    Fast quantitative evaluation of the resolution of compressed sensing tomographic reconstructions
    Proc. 4th Intl. Mtg. on image formation in X-ray CT, 69-72, Bamberg (2016)

    K. Dremel, D. Althoff, S. Zabler
    CT alignment correction in iterative reconstruction methods
    Proc. 4th Intl. Mtg. on image formation in X-ray CT, 137-140, Bamberg (2016)

    J. Dittmann, A. Eggert, M. Lambertus, J. Dombrowski, A. Rack. S. Zabler
    Finding robust descriptive features for the characterization of the coarsening dynamics of three dimensional whey protein foams
    Journal of Colloid and Interface Science Vol. 467, Pages 148-157 (2016) 
    http://dx.doi.org/10.1016/j.jcis.2015.12.055

    A. Balles, Ch. Fella, J. Dittmann, W. Wiest, S. Zabler, and R. Hanke
    X-ray grating interferometry for 9.25 keV design energy at a liquid-metal-jet source
    AIP Conf. Proc. 1696, 020043 (2016)
    http://dx.doi.org/10.1063/1.4937537

    M. Kiunke, C. Stritt, R. Schielein, F. Sukuwski, A. Hölzing, S. Zabler, J. Hofmann, A. Flisch, St. Kasperl, U. Sennhauser, R. Hanke
    ROSI and GEANT4 - A comparison in the context of high energy X-ray physics
    Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Volume 377, Pages 50-58  (2016)
    http://dx.doi.org/10.1016/j.nimb.2016.04.029

    A. Detterbeck, M. Hofmeister, E. Hofmann, D. Haddad, D. Weber, A. Hölzing, S. Zabler, M. Schmid, K.-H. Hiller, P. Jakob, J. Engel, J. Hiller, U. Hirschfelder
    MRI vs. CT for orthodonic applications: comparison of two MRI protocols and three CT (multislice, cone-beam, industrial) technologies
    J Orofac Orthop (2016)
    http://dx.doi.org/10.1007/s00056-016-0028-2

    A. Detterbeck, M. Hofmeister, D. Haddad, D. Weber, M. Schmid, A. Hölzing, S. Zabler, E. Hofmann, K.-H. Hiller, P. Jakob, J. Engel, J. Hiller, U. Hirschfelder
    Determination of the mesio-distal tooth width via 3D imagin techniques with and without ionizing radiation: CBCT, MSCT, and µCT versus MRI
    http://dx.doi.org/10.1093/ejo/cjw047

    A. Balles, S. Zabler, T. Ebensperger, C. Fella, R. Hanke
    Propagator based formalism for optimizing in-line phase contrast imaging in laboratory X-ray setups
    Review of Scientific Instruments 87, 093707 (2016)
    http://dx.doi.org/10.1063/1.4962713

    P. Stahlhut, K. Dremel, J. Dittmann, J. M. Engel, S. Zabler, R. Hanke
    First results on laboratory nano-CT with a needle reflection target and an adapted toolchain
    http://dx.doi.org/10.1117/12.2240561

    K. Blum, W. Wiest, Ch. Fella, A. Balles, J. Dittmann , A. Rack, D. Maier, R. Thomann, B. Spies, R. Kohal, S. Zabler, K. Nelson
    Fatigue induced changes in conical implant-abutment connections
    Dental Materials, Vol 31, Issue 11, november 2015, Pages 1415-1426
    http://dx.doi.org/10.1016/j.dental.2015.09.004

    W. Wiest, S. Zabler, A. Rack, C. Fella, A. Balles, K. Nelson, R. Schmelzeisen and R. Hanke
    In situ microradiograühy of fatigue-loaded dental two-piece implants
    Journal of Synchrotron Radioation (2015). 22, 1492-1497
    http://dx.doi.org/10.1107/S1600577515015763

    M. Ullherr, S. Zabler
    Correction multi material artifacts form single material phase retrieved holo-tomograms with an simple 3D Fourier method
    Optics Express Vol. 23, Issue 25, pp. 32718-32727
    http://dx.doi.org/10.1364/OE.23.032718

    C. Fella, A. Balles, S. Zabler, R. Hanke, R. Tjeung, S. Nguyen and D. Pelliccia
    Laboratory x-ray microscopy on high brilliance sources equipped with waveguides

    J. Appl. Phys. 118, 034904 (2015)
    http://dx.doi.org/10.1063/1.4927038

    W. b. Herppich, U. Matsushima, W. Graf, S. zabler, Ma. Dawson, G. Choinka, I. Manke
    Synchrotron X-ray CT of rose peduncles - evaluation of tissue damage by radiation
    http://dx.doi.org/10.3139/120.110675

    Ph. Stahlhut, Th. Ebensperger, S. Zabler, R. Hanke
    A laboratory X-ray microscopy setup using a field emission electron source and micro-structured reflection targets, Nuclear Instruments and Methods in Physics
    Research Section B, 324 (2014) 4-10
    http://dx.doi.org/10.1016/j.nimb.2013.12.028

    Th. Ebensperger, Ch. Rimbach, S. Zabler, R. Hanke
    Influences on 3D image quality in a high resolution X-ray laminography system
    JINST 2014 Volume 9 C05030
    http://iopscience.iop.org/1748-0221/9/05/C05030/

    A. Eggert, M. Müller, F. Nachtrab, J. Dombrowski, A. Rack, and S. Zabler
    High-speed in-situ tomography of liquid protein foams.
    International Journal of Materials Research: Vol. 105, No. 7 (2014), pp. 632-63
    http://dx.doi.org/10.3139/146.111057

    Th. Ebensperger, Ch. Rimbach, S. Zabler, R. Hanke
    Detector Characterization for a High Resolution Laminography System
    Frühjahrstagung der Deutschen Physikalischen Gesellschaft 2013, Regensburg

    Ch. Rimbach, Th. Ebensperger, S. Zabler, R. Hanke
    Characterization and Application of an Ultra-High Resolution Laminography System
    European Congress and Exhibition and Advanced Materials and Processes, Sevilla

    Th. Ebensperger, Ch. Rimbach, S. Zabler, R. Hanke
    Influences an 3D Image Quality in a High-Resolution X-ray Laminography System
    Journal of Instrumentation (accepted)

    U. Matsushima, W. Graf, S. Zabler, I. Manke, M. Dawson, G. Choinka, A. Hilger,  W. B. Herppich
    3-D-analysis of plant microstructures; advantages and limitations of synchrotron X-ray micro-tomography
    International Agrophysics 27:23-30 2013
    http://www.international-agrophysics.org/en/artykul/144

    T, Schoen, T. Fuchs, R. Hanke
    A Translation-Based Data Acquisition Method for Computed Tomography: Theoretical Analysis and Simulation Study
    MEDICAL PHYSICS Volume 40 Issue 8, Article Number: 081922, August 2013
    http://onlinelibrary.wiley.com/doi/10.1118/1.4813896/abstract

    S. Zabler, A. Ershov, A. Rack, F. Garcia-Moreno, T. Baumbach, J. Banhart
    Particle and liquid motion in semi-solid aluminium alloys: a quantitative in situ micro-radioscopy study
    Elsevier Editorial System(tm) for Acta Materialia, 2012
    http://doi.org/10.1016/j.actamat.2012.10.047

    Th. Ebensperger, Ph. Stahlhut, A. Balles, F. Nachtrab, R. Hanke
    A comparison of different sources for lab-based X-ray microscopy
    14th International Workshop on Radiation Imaging Detectors, Figureira da Foz, Portugal, 2012
    http://dx.doi.org/10.1088/1748-0221/7/10/C10008

    Ch. Fella, S. Zabler, F. Nachtrab, A. Dietrich, Th. Ebensperger, N. Uhlmann, R. Hanke
    Frontiers of high-resolution and high-speed CT in industry and research
    Proc. SPIE 8506, Developments in X-Ray Tomography VIII, 2012
    http://dx.doi.org/10.1117/12.964588

    Ph. Stahlhut, Th. Ebensperger, S. Zabler, R. Hanke
    Nano CT for the Laboratory, 11th International Conference on X-ray Microscopy
    Shanghai, China

    A. Balles, S. Zabler, Th. Ebensperger, R. Hanke
    Optimized detector concept for inline phase contrast and Born-type retrieval algorithms using polychromatic micro- and nano-focus X-ray Sources
    11th biennial Conference on High Resolution X-ray Diffraction and Imaging, St. Petersburg, Russia, 2012

    F. Bayer, S. Zabler, C. Brendel, F.  Nachtrab, G. Anton, R. Hanke
    Optimization of grating-based X-ray darkfield imaging
    11th biennial Conference on High Resolution X-ray Diffraction and Imaging, St. Petersburg, Russia, 2012

    S. Zabler, T. Rack, A. Rack, K. Nelson
    Fatigue induced deformation of taper connections in dental titanium implants
    Int. J. Mat. Res. (formerly Z. Metallkd.), 103; page 1-10, 2012
    doi: 10.3139/146.012021

    S. Zabler, T. Ebensperger, C. Fella, R. Hanke
    High-resolution X -ray imaging for lab-based materials research
    Conference on Industrial Computed Tomography, Wels, Austria 2012
    www.ndt.net/article/ctc2012/papers/127.pdf

    U. Matsushima, A. Hilger, W. Graf, S. Zabler, I. Manke, M. Dawson, G. Choinka, W. B. Herppich
    Calcium oxalate crystal distribution in rose peduncles: Non-invasive analysis by synchrotron X-ray micro-tomography
    Postharvest Biology and Technology 72 27-34, 2012
    http://doi.org/10.1016/j.postharvbio.2012.04.013

    S. Zabler, C. Fella, A. Dietrich, F. Nachtrab, M. Salamon, V. Voland, T. Ebensperger, S. Oeckl, R. Hanke, N. Uhlmann
    High-Resolution and High-Speed CT in Industry and Research
    Proc. SPIE 8506, Developments in X-Ray Tomography VIII, 850617 (October 17, 2012)
    http://proceedings.spiedigitallibrary.org/proceeding.aspx?articleid=1384283

    T. Ebensperger, P. Stahlhut, F. Nachtrab, S. Zabler, R. Hanke,
    Comparison of different sources for laboratory X-ray microscopy
    Journal of Instrumentation Volume 7 October 2012
    http://iopscience.iop.org/article/10.1088/1748-0221/7/10/C10008/meta

    Frank Nachtrab , Thomas Ebensperger , Bernhard Schummer, Frank Sukowski, Randolf Hanke
    Laboratory X-ray microscopy with a nano-focus X-ray source
    13th International Workshop on Radiation Imaging Detectors, Zürich, 2011
    http://dx.doi.org/10.1088/1748-0221-6-11-C11017

    M. Firsching, F. Nachtrab, N. Uhlmann, R. Hanke
    Multi-Energy X-Ray Imaging as a Quantitative Method for Materials Characterization
    Advanced Materials, Wiley-VCH Verlag Weinheim, 2011
    https://doi.org/10.1002/adma.201004111

    Nachtrab F.; Weis S.; Kessling P.; Hanke, R. et al.
    Quantitative material analysis by dual-energy computed tomography for industrial NDT applications
    Nuclear Inst. & Meth. in Phys. Research Sec. A-Accelerators Spectrometers Detectors and Associated Equipment, Vol: 633 Supplement: 1
    http://www.sciencedirect.com/science/article/pii/S0168900210013446

    Hanke, R.;
    High Resolution Limited Angle Computed Tomography with Electron Probe Microanalyzer,
    Proceedings, European Congress and Exhibition on Advanced Materials and Processes (Euromat),
    Sep. 12 – 15, 2011, Montpellier, France

    M. Teßmann, S. Mohr, S. Gayetskyy, U. Haßler, R. Hanke
    Automatic Determination of Fiber-Length Distribution in Composite Material using 3D CT Data
    EURASIP Journal on Advances in Signal Processing, S. Article ID 545030, 2010
    doi:10.1155/2010/545030

    B. Damm, R. Schmitt, A. Rehbein, R. Volk, E. Warrikhoff, R. Hanke, S. Kasperl, C. Funk, J. Hiller, M. Krumm, F. Sukowski, N. Uhlmann, R. Behrendt
    Measurement of Shafts in the Production Process based on X-Rays
    Optics, Photonics and Digital Technologies for Multimedia Applications, Proceedings of SPIE Volume: 7723, ISBN 9780819481962, 2010
    doi:10.1117/12.853592

    R. Hanke, F. Nachtrab, S. Burtzlaff et al.
    Setup of an Electron Probe Micro Analyzer for Highest Resolution Radioscopy
    Nuclear Instruments & Methods in Physics, Research Section A, 607 (1) 173-175, 2009
    http://doi.org/10.1016/j.nima.2009.03.151

    F. Nachtrab, T. Hofmann, N. Uhlmann, R. Hanke
    Simple Solutions for Spectroscopic, Photon Counting X-ray Imaging Detectors
    Conference Record IEEE NSS/MIC Orlando, 2009
    doi:10.1109/NSSMIC.2009.5402242

    T. Wenzel, T. Stocker, R. Hanke
    Searching for the Invisble using Fully Automatic X-ray Inspection
    Foundry Trade Journal of the Institute of Cast Metals Engineers, Vol. 183, No 3666, 2009

    N. Uhlmann, J. Pavlovic, M. Hilbinger, R. Hanke, et al.
    Possibilities of High Resolvent X-ray Computer Tomography in the Analysis of Texture Features of Metallic Material
    Congress on Engine Casting, Vol 2061, 81-89, Magdeburg, 2009
    doi:10.1109/NSSMIC.2009.5402242

    Publikationen 200M. Salamon, R. Hanke, et al.
    Realization of a Computed Tomography Setup to Achieve Resolutions below 1 µm
    Nuclear Instruments & Methods in Physics, Research Section A, 591 (1) 50-53 (2008)

    R. Hanke, T. Fuchs, N. Uhlmann
    X-ray based Methods for Non-destructive Testing and Material Characterization
    Nuclear Instruments & Methods in Physics, Research Section A, 591 (1) 14-18 (2008)

    M. Salamon, R. Hanke, et al.
    Comparison of Different Methods for Determining the Size of a Focal Spot of Microfocus X-ray Tubes
    Nuclear Instruments & Methods in Physics, Research Section A, 591 (1) 54-58 (2008)

    U. Haßler, M. Rehak, R. Hanke
    Carbon Fiber Preform Inspection by Circular X-ray Tomosynthesis
    Nuclear Science Symposium/Medical Imaging Conference, Conference Record IEEE NSS/MIC Dresden 2008

    R. Hanke, T. Fuchs
    Task Driven Design of X-ray Systems for Industrial Inspection
    Nuclear Science Symposium/Medical Imaging Conference, Conference Record IEEE NSS/MIC Vols 1-9, 5425-5429, Dresden 2008
    doi:10.1109/NSSMIC.2008.4775230

    F. Nachtrab, M. Salamon, S. Burtzlaff, F. Porsch, W. Johannson, N. Uhlmann, R. Hanke
    Progress in Sub-Micrometer Resolution Computed Tomography
    IEEE Nuclear Science Symposium/Medical Imaging Conference, Conference Record IEEE NSS/MIC Vols 1-9, 5492-5495, Dresden 2008

    Hanke, R.,
    Microanalysis by Volume Computed Tomography
    Hanke, R., Microanalysis by Volume Computed Tomography – State of the Art Review,
    Imaging &Microscopy, Vol 5, page 40-43, GIT Verlag Darmstadt, 2003